600A T Deadbreak Connector
1. Ipurasitiki inodzivirirwa zvizere, yakavharwa zvizere, inobatika asi ine simba.
2. Inoshandiswa zvakanyanya mumatransformer ekunze, matransformer emhando yebhokisi rekuAmerica, mayuniti makuru ering, mabhokisi ebazi retambo, matransformer epasi pevhu nemimwe michina yemagetsi yekubatanidza.
3. Inoshandisa EPDM (triple rabber) yemhando yepamusoro.
  • Ruzivo rweChigadzirwa

  • Matagi eChigadzirwa

Anhuang inonyanya kugadzira Deadbreak Connector, tinopa Deadbreak Connector yemhando yepamusoro.

Kushandiswa kwemitemo:

● Sisitimu yekubatanidza inochengetedzwa inoparadzaniswa yemasisitimu ekuparadzira ari pamusoro apa; ANSI / IEEE Std386-2006600V

● Majaketi e semiconductor akajeka ekubatanidza tambo dzine voltage yakakwira uye zvinobatanidza zvinodzivirirwa zvinopatsanurwa;

● Tambo dzemagetsi dzakaiswa muchina wekudzivirira kupisa pamwe chete nezvishongedzo zvadzo zvine voltages dzakatarwa dziri pamusoro pe1 kV (Um = 1.2 kV) kusvika 30 kV (Um - 35 kV);

● Nzira dzekuyedza dzezvishongedzo zvetambo dzemagetsi dzine voltage dzakatarwa kubva pa6 kV (Um = 7.2 kV) kusvika pa30 kV (Um = 35 kV);

●Tambo dzemagetsi dzakaiswa insulation pamwe chete nezvishongedzo zvadzo zvine voltage dzakatarwa kubva pa1 kV(Um = 1.2 kV) kusvika pa35 kV (Um = 40.5 kV).

● Kubatanidzwa kwemidziyo yekudzivirira kupisa uye yekugovera ine simba guru GB/T4109-1999

● Mamiriro ehunyanzvi ebhavhu remagetsi ane simba rakawanda;

● Simbi isina mipata - zvinomisa kukwira kwe oxide;

● Tambo dzemagetsi dzine makoni ekuwedzera - Zvikamu zvinogadzirisa zviyero zvemaoko uye zvinogadziriswa zvinopatsanurwa zveUm pasi pe35 kV DIN 47636-7-1990.

15kV/24kV 600A Class T Deadbreak Connector inoshandiswa kudzima tambo yepasi pevhu ine voltage yakawanda kumatransformer, switch, switchgear nezvimwe zvishandiso. Yakachengetedzwa zvizere, inonyudzwa mumvura. Masisitimu edu anopa nzvimbo yekuyedza ine capacitive yakafanana neyakaenzana nema test points pa 200A elbow connectors. Izvi zvinobvumira kushandiswa kweFault Indicators. MaT connectors anosanganisira T Cable Connector uye load break bushing extender. Anopawo nzvimbo iri nyore yeMOVE arrester kana grounding elbow. Anowanikwa conductor cross section ine 25-500m² ye 24kV cable.

 

Kuongororwa kwemagetsi kunoenderera mberi

Chinhu

15kV data

25kV data

35kV data

Kuenderera mberi kwemagetsi ekushanda

8.7kV/14.4kV

15.2kV 26.3kV

26kV/35kV

AC inodzivirira magetsi

45kV/1min

55kV/5min

117kV/5min

DC inodzivirira magetsi

53kV/15min

78kV/15m mukati

104kV

1.5/50 μs Kurova kwemoyo nemagetsi ekumira

95kV

125kV

215kV

Voltage yekubuda kwechikamu

13kV

22kV

45kV

 

Chiyero chazvino

Chinhu

200AMP

600AMP

Kutakura mutoro

magetsi

Inowanikwa mu14.4kV uye 200A kagumi pasi payo

kupwanya nekuvhara mashandiro

 

Chikanganiso chakavharwa

magetsi

Inowanikwa mu14.4kV, 1000N0.175 kamwe chete pasi

nekutadza kushanda kwakavharwa

 

Kupisa kwakasimba

magetsi

16kA 1s

30kA 2s

Kutsungirira kwepamusoro-soro

magetsi

10kA

105kA

 img2222

Nhamba yeReferensi Chikamu chemuchinjiko wemudhudhudhu (mm²) Tambanudza huwandu pamusoro pekudzivirira (mm)
AH TT 24/600-35

35

18.6

AH TT 24/600-50

50

19.6

AH TT 24/600-70

70

21

AH TT 24/600-95

95

22.6

AH TT 24/600-120

120

24.2

AH TT 24/600-150

150

25.6

AH TT 24/600-185

185

27.2

AH TT 24/600-240

240

28.7

AH TT 24/600-300

300

31.1

AH TT 24/600-400

400

33.2

Kubvunza